|
Product Details:
Payment & Shipping Terms:
|
2000 ml Mandatory Minute Ventilation / MMV Medical Ventilators for Ambulance Room
Great Visibility: 12.1" high resolution visiual screen; Four different waves in one screen simultaneously
Greater Felexbility: Unique & practical ventilator menu for different respiration mode;
Greater Safety: Comprehensive monitoring & alarm system, effective data for safety and accuracy on operation;
Rotate screen freely, conviniently watch patient in any position;
Low noise air compressor provide stabke, secure, and permanent motivation;
FiO2: 21% to 100%,
Alarm recording function for tracking data.
Applications:
This machine can be used in respiratory management of after anesthestized operation, ambulance room, ICU, CCU, etc.
The patient type: Adult, Pediatric
Specifications:
Operating Modes
|
Volume Control Ventilation (VCV), Assisted/Controlled Pressure Control Ventilation (PCV), Assisted/Controlled Pressure Support Ventilation (PSV), SIMV(VCV)+PSV SIMV(PCV)+PSV Mandatory Minute Ventilation (MMV) |
Parameter Selection according to the operating mode
|
FiO2: 21% to 100% PEEP/CPAP: 0 to 40 cmH2O Inspiratory Sensitivity: Flow triggered: 0.5 to 20 L/min, OFF Pressure triggered: -1 to -20 cmH2O, OFF Tidal Volume: 20 to 2000 mL Breath frequency: 1 to 100 bpm I:E Ratio: 5.0 : 1 to 1 : 5.0 Inspiratory plateau: 0 to 50% Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave SIGH: 1.0 to 2.0 Breath frequency(SIMV): 2 to 40bpm Inspiratory time (SIMV): 0.1 to 12 S Pressure Support Ventilation (PSV): 0 to 40 cmH2O Expiratory Sensitivity for PSV : 10% to 75% of the initial flow Maximum Inspiratory time (PSV): 1.0 to 8.0 S Pressure Control Ventilation(PCV): 0 to 40 cmH2O Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL Backup Rate (PSV): 2 to 40 bpm Object Tidal Volume(MMV): 20 to 2000 mL Ventilation volume(MMV): 0.5 to 40.0 L/min |
Alarms
|
High tidal volume Low tidal volume High minute ventilation Low minute ventilation High respiratory rate Low respiratory rate High peak pressure Low peak pressure High PEEP pressure Low PEEP pressure Low pressure of one gas (oxygen or air) Apnea AC power fail Batterydisconnect Low battery Circle block |
Other features and controls |
12.1 TFT Pressure vs time curve Flow vs time curve Volume vs time curve Pressure vs volume loops Flow vs volume loops Scale of graphics Nebulizer |
Power requirement |
Main power: from 85 to 265VAC 47-63HZ Automatic voltage switch Internal battery: 12VDC; 7AH Automatic recharge. Estimated duration: more than 2 hours when completely charged. The display shows an icon with the charge level. |
Pneumatic requirement |
Oxygen: pressure 2.8 to 6 bar ISO5359 connector Air: pressure 2.8 to 6 bar ISO 5359 connector |
Packing size |
First in Carton, then packing in Synthetic case, Size: 116 x 66 x 60 Gross weight: 98kg |
Competitive Advantage:
Great Visibility: 12.1" high resolution visiual screen; Four different waves in one screen simultaneously
Greater Felexbility: Unique & practical ventilator menu for different respiration mode;
Greater Safety: Comprehensive monitoring & alarm system, effective data for safety and accuracy on operation;
Rotate screen freely, conviniently watch patient in any position;
Low noise air compressor provide stabke, secure, and permanent motivation;
FiO2: 21% to 100%,
Alarm recording function for tracking data.
Contact Person: Ms.
Fax: 86-10-60805205