Product Details:
Payment & Shipping Terms:
|
High Light: | Anaesthesia Workstation,Veterinary Anaesthesia Machine |
---|
Electrical F-t 65bpm General Anesthesia Equipment with VCV,PCV Respiration Mode
Aluminium alloy frame has rail, can be upgraded with functions, eg, CO2 Monitor, Multi-parameter monitor, Anesthesia depth monitor, etc.
With Volume & pressure ventilation modes,
Advanced electromagnetic valve ensures accurate tidal volume and compensation, use advanced differential pressure flow sensor to monitor tidal volume,
With 10.4” TFT color screen, waveform showed: P-t, F-t, V-t; Loops: F-v, V-p
Fresh gas outlet is in front of frame, the user can easily connect with Jackson –Rees circuit,
Working interfaces for adult and pediatric are separated; the doctor can choose interface according to patient type,
Classical CO2 circle absorber is with 2 canisters, low resistance, minimum gas leakage,
Optional: O2, N2O Yoke device. When main gas supply is failed, the backup gas supply can be automatically started.
Applications:
The Anesthesia Machine which is researched and produced by the Manufacturer Readeagle is a movable unit integrated with anesthesia and ventilation, which could be applied to closed anesthesia, semi-closed anesthesia, and semi-open anesthesia, and be applicable to Adult / Pediatric inhalation anesthesia, oxygen supply, resuscitation and respiratory management.
Specifications:
Patient type |
Adult, pediatric |
Respiration mode |
IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO |
Display: |
10.4〞TFT color screen |
Waveform |
P-t, F-t, V-t, F-v, V-p |
Tidal Volume |
20~1600ml |
Respiratory frequency |
1~65bpm |
I:E ratio |
8:1~1:8 |
Inspiration pause |
0~55%Ti |
Inspiration Pressure |
1~60cmH2O |
Trigger Pressure |
-20~20cmH2O |
Monitoring parameters
|
O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, PEEP, I:E ratio, Pmean, |
Alarm parameters
|
High pressure alarm, Low pressure alarm, O2 concentration alarm, MV alarm, O2 source failure alarm, AC power failure alarm |
Pressure alarm setting |
High pressure alarm set 1~60cmH2O Low pressure alarm set 0~20cmH2O |
O2 concentration alarm setting |
High: 21~99% Low: 21~50% |
MV alarm setting |
MV high alarm set 10~99L/min MV low alarm set 0~40L/min |
Gas source pressure |
O2: 0.25Mpa~0.65MPa N2O: 0.25Mpa~0.65MPa Air: 0.25Mpa~0.65MPa |
O2 + N2O + Air flowmeter |
Hypoxic guard system, keep oxygen concentration isn`t lower than 25% |
Oxygen flush |
25L/min~75L/min |
Circle absorber |
Safety valve pressure limit: 6Kpa Good air tightness, high reliability and minor respiration impedance With Manual/ Ventilation switch |
Ventilator performance
|
Max. safety pressure : ≤6.0KPa Compliance: ≤40m/KPa Electrical Safety: Meet requirements for Class I, type B equipment specified in EN60601-1 Medical Electrical equipment: Part one: General requirement for safety. Noise: ≤ 65 dB(A) |
Physical specification
|
Whole machine: Length: 920mm Width: 560mm Height: 1490mm Weight: 125Kg Wheels: 100mm (diameter), 125mm (height), with brakes on the front two wheels |
Environments
|
Temperature: Working: 18-36℃ Storage: -20-55℃ Comparative humidity: Working: 45%-75% Storage: ≤93% Atmosphere: Working: 0.95~1.05 bar Storage: 500hpa~1060hpa, Altitude: Working: 500 to 800 mmHg (3565 to -440m) Storage: 375 to 800 mmHg (5860 to -440m) |
Competitive Advantage:
The Anesthesia Ventilator is one independent part, conveniently upgraded with new software,
Aluminium alloy frame has rail, can be upgraded with functions, eg, CO2 Monitor, Multi-parameter monitor, Anesthesia depth monitor, etc.
With Volume & pressure ventilation modes,
Advanced electromagnetic valve ensures accurate tidal volume and compensation, use advanced differential pressure flow sensor to monitor tidal volume,
With 10.4” TFT color screen, waveform showed: P-t, F-t, V-t; Loops: F-v, V-p
Fresh gas outlet is in front of frame, the user can easily connect with Jackson –Rees circuit,
Working interfaces for adult and pediatric are separated; the doctor can choose interface according to patient type,
Classical CO2 circle absorber is with 2 canisters, low resistance, minimum gas leakage,
Optional: O2, N2O Yoke device. When main gas supply is failed, the backup gas supply can be automatically started.
Contact Person: Ms.